| Zones | 16 conventional zones expandable to 28 using FF501Z boards |
| Sounder Circuits | 4 conventional sounder circuits |
| Enclosure | Robust metal enclosure with lift-off lid & heavy-duty base connections |
| Design | Microprocessor-based control panel |
| Fault Indicators | Open circuit, short circuit, head-out, sounder, battery & power supply faults |
| Inputs/Outputs | Non-latching class change input, latching fire & non-latching fault outputs |
| Wiring Facility | Zone selectable short circuit as fire, no resistors required in call points |
| Repeater Support | Up to 8 two-wire repeaters per main panel |
| Battery Space | Space for 2 × 12V 7Ah VRLA batteries (not included) |
| Compatibility | Compatible with virtually all conventional fire detectors |
| Additional Feature | Fault buzzer mute facility |
Description
The 16 Zone MFP Fire Panel is a microprocessor-based conventional fire alarm control panel designed for reliable zone monitoring and system expansion. It features sixteen conventional zones expandable to twenty-eight using plug-in expansion boards, along with four conventional sounder circuits. Housed in a robust metal enclosure with lift-off lid and heavy-duty base connections, the panel supports multiple fault indications, repeater connectivity, and flexible wiring options without the need for resistors in call points. It accommodates two 12V 7Ah VRLA batteries (not included) and is compatible with most conventional fire detectors, making it a versatile solution for fire safety installations.
- The panel provides sixteen conventional zone circuits that can be expanded to twenty-eight zones using FF501Z plug-in expansion boards for scalable fire detection coverage.
- It is built with a robust metal enclosure featuring a lift-off lid and heavy-duty base connections for durable and secure installation.
- A microprocessor-based design ensures stable operation, reliable monitoring, and accurate fault detection across all zones and circuits.
- The system includes four conventional sounder circuits and supports a non-latching class change sounder input along with latching fire and non-latching fault outputs via an expansion loom.
- Dedicated indicators are provided for open circuit, short circuit, detector head removal, sounder faults, and battery or power supply faults for quick diagnostics.
- The panel supports zone-selectable short circuit as fire facility, eliminating the need for resistors in call points and simplifying wiring.